ATS cuts over systems
Smartgen, Deepsea, ComAp and Harsen controllers, ATS transfer systems and parallel running systems.
| Category | Genset Control Systems |
| Standard controller | Smartgen, other brands on request |
| Standard alternator | Stamford, other brands on request |
| Testing | No load, 50 %, 75 %, full load and 110 % load before shipment |
ATS Cuts Over System
Unite Power series Automatic Transfer Switches are an integral part of the power generation process
Allowing smooth and immediate transfer of electrical current between multiple sources and the load
When the generator is operating, the transfer switch prevents dangerous feedback of current to the utility's system
It also ensures that different sources are fully synchronized before their power is combined or loads are transferred
Which is imperative of safe operation
The transfer switch senses when utility power is interrupted, and starts up the generator if the utility power remains absent
In about five to ten seconds, when the generator is producing full power
The transfer switch disconnects the load from the utility and connects it to the generator
Restoring electricity to the load. The transfer switch continues to monitor utility power, and when it is restored
Switches the load from the generator back to the utility
Once the generator is disconnected, it goes through a cool-down routine and is automatically shut down. ATS size is availble from 30 to 3200Amp
Choosing the right ATS for the generator set
Generator Set Current: = Genset KVA*1000/Voltage/1.732
ATS Size sould be 120% of the generator set current
For emergency power usage in building. Auto transfer switch (ATS) is essential
ATS can auto transfer load from mains power supplying to emergency power
When the main power supplying failure or voltage drop below 80% of normal voltage
ATS will auto start emergency generator set after a preset
Time of 0-10sec(adjustable according to the users). Once generator reach reach at rated speed
The ATS will transfer the load to emergency generator sets automatically
The ATS has large variety current as well as load transform is feasible(20-2500A)
EndFragment
FAQ
The power in kVA or kW, the frequency, the voltage, and whether you need open, soundproof, container or trailer type. Tell us the quantity and the destination port as well and we will quote delivered.
Yes. Smartgen and Stamford are standard. Deepsea, ComAp and Harsen controllers and Leroy Somer, Marathon, Engga or Kaijielie alternators are available on request.
Yes. Sets are tested at no load, 50 % load, 75 % load, full load and 110 % load, and ship with a test report signed by the technical department.
Send the power, the frequency and the voltage and we will confirm the model and the price.